Experiments › Chemistry
Why does white crust form in kettles?
Water Hardness
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 5 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does a crusty white ring build up inside tea kettles and water pipes?
Show the answer
Water dissolves invisible minerals from rocks deep underground. Today you will trap these hidden minerals into solid chalk and track them with an electric conductivity probe.

Introduction
Why Does White Crust Form in Kettles?
When rainwater trickles through limestone rocks, it dissolves minerals like calcium. We call this hard water. You cannot see the dissolved calcium with your eyes. But when hard water boils, calcium leaves behind a white rocky crust called limescale. In this experiment, we add washing soda drops to hard water. The minerals lock together into solid chalk flakes. A conductivity probe tracks how many free mineral charges remain, pinpointing exactly how hard the water is.
Driving question: Why does chalky crust form in kettles, and how can we measure dissolved minerals in tap water?
What you will learn
Today you will discover
- I can explain what makes water hard and why it conducts electricity.
- I can observe a solid precipitate forming in a liquid reaction.
- I can find the turning point on a V-shaped graph to measure water hardness.
- I can safely use a buret and conductivity sensor to collect accurate data.
- I can describe why water hardness matters for home pipes and appliances.
Why it matters: Hard water clogs city pipes, ruins home water heaters, and stops soap from foaming. Water scientists test hardness daily.
Safety first
Lab Rules for Today
- Wear chemical splash goggles and protective gloves throughout the lab.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Never taste or drink any liquid in the lab, even if it looks like clear water.
- Handle the glass buret gently. Never force the clamp or tap the buret tip on the beaker.
- Keep tablet and sensor cables away from beaker liquids to avoid spills.
- Wipe up droplets immediately. Wash hands with soap when you finish.
What you need
- Go Direct Conductivity Probe1
- Stir Station1
- buret1 (50 mL) · teacher
- buret clamp1 · teacher
- 150 mL beaker1
- 25 mL graduated cylinder1
- magnetic stir bar1
- clear solution in a reagent bottle30 mL (~0.10 M calcium chloride)
- clear liquid in a wash bottle50 mL (0.10 M sodium carbonate)
- Distilled water wash bottle1 bottle (200 mL)
- Tablet running Graphical Analysis1

Step 1 of 5
Measure hard water into the beaker
- Use the 25 mL cylinder to measure 10 mL of calcium chloride solution.
- Pour it into your 150 mL beaker.
- Add 25 mL of distilled water from your wash bottle so the liquid is deep enough.
- Carefully slide the magnetic stir bar down the beaker wall.
- Goggles and blue gloves are on.
- The beaker sits securely on the lab bench.
- Cylinder read at eye level on a flat surface.
Careful: If you drop the stir bar heavily, it can crack the beaker base. Spilled calcium chloride can irritate skin. Tilt the beaker gently and slide the stir bar down the inner wall.

Step 2 of 5 Teacher does this
Adult clamps and fills the buret
- The teacher checks that the buret stopcock is closed tight.
- The teacher fills the buret with 0.10 M sodium carbonate solution up near the 0.0 mL mark.
- Drain a few drops into a waste cup to flush out any bubble in the tip.
- Record the initial liquid level on the buret scale.
- Buret clamp is firmly tightened to the ring stand.
- Waste beaker is placed under the buret tip.
- Teacher wears purple gloves and splash goggles.
Careful: Sodium carbonate solution can splash when you pour it. An open stopcock can cause a table spill. Only the adult fills the buret at eye level with a small funnel. Keep the stopcock closed.

Step 3 of 5
Assemble the probe and Stir Station
- Place the beaker onto the Stir Station platform.
- Insert the Go Direct Conductivity Probe into the support arm beside the buret.
- Lower the probe so the oval hole near the tip is completely underwater.
- Turn on the stir knob to spin gently. Make sure the stir bar never hits the probe.
- Stir knob starts at zero (off).
- Probe hole is fully submerged.
- Probe is positioned to the side so the stir bar spins freely.
Careful: A fast stir bar can hit the probe. This can break glassware or chip the sensor. Turn the knob slowly to create a smooth, gentle swirl with no splashes.

Step 4 of 5
Record the baseline reading at 0 mL
- In Graphical Analysis, tap Collect to start data collection.
- Look at the live conductivity reading before you add liquid from the buret.
- Once the number is steady (around 6400 µS/cm), tap Keep.
- Type 0 as the volume. Tap Keep Point.
- The stir bar spins smoothly without splashes.
- Buret stopcock is closed tight.
- Conductivity reading is steady on the screen.
Careful: If you type the wrong buret volume into the app, you ruin the graph scale. Double-check the buret level before you type each value.

Step 5 of 5
Add sodium carbonate 1 mL at a time
- Carefully open the stopcock to add exactly 1.0 mL of sodium carbonate.
- Watch white clouds of solid chalk form in the beaker as it swirls.
- Wait about 5 seconds for the reading to steady. Tap Keep.
- Type the exact buret volume. Tap Keep Point.
- Repeat in 1.0 mL steps until you reach 15.0 mL total.
- One student controls the buret stopcock.
- One student reads the volume at eye level.
- One student operates the tablet screen.
Careful: If the liquid flows too fast, you can overshoot the 1.0 mL mark. Turn the stopcock handle slowly with two fingers. Close it promptly.
0 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Level AS & A Level, Chemistry, chapter 21: Further aspects of equilibria
Versions and what each needs
- Why does white crust form in kettles? (burette)
AP Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct Conductivity Probe - Why does white crust form in kettles? (drop counter)
AP Chemistry, 75 min, Based on a Vernier lab
Needs: Go Direct Conductivity Probe, Go Direct Drop Counter
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.