Experiments › Chemistry

Why is acid rain eating statues?

Acid Rain Effect on Marble

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 11 steps. To run it with the sensors, record data and take the quiz, students use the app.

A weathered historic stone statue in heavy rain

Wonder

Why are ancient stone statues slowly losing their carved faces?

Show the answer

Air pollution turns natural rainwater acidic. This acid chemically eats away marble rock, releasing gas bubbles. Today you will measure this destruction in real time.

Close-up comparison of freshly carved marble and acid-weathered marble

Introduction

The Disappearing Stone Carvings

For centuries, carved marble statues stood proud in town squares. Today, many look melted or worn smooth. What is destroying solid rock? Rainwater! Smoke from factories and traffic carries acidic gases into clouds. When rain falls, it reacts chemically with the stone, turning solid rock into dissolved salts and gas. In this lab, you will trap that gas and measure the pressure to uncover how fast acids destroy marble.

Driving question: Why does acid rain eat away historic stone statues?

What you will learn

Today you will find out

  • I can explain how acid rain damages marble and limestone statues.
  • I can use a gas pressure sensor to monitor a gas-producing reaction.
  • I can compare how different acids wear away marble.
  • I can safely participate in a lab that uses strong acids.
  • I can explain how environmental pollution threatens historical monuments.

Why it matters: Architects, heritage conservators, and city planners must protect priceless monuments like the Taj Mahal and Parthenon from air pollution.

Safety first

Lab Rules for Strong Acids

  • Wear splash goggles, chemical gloves, and a lab coat at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • The acids used today (6 M HCl and 6 M H2SO4) are concentrated and cause severe chemical burns.
  • Only your teacher will measure, pour, and handle the acid solutions.
  • Look for the ADULT NEEDED badge on high-risk steps.
  • Never open the sealed flask without adult guidance while pressure increases.
  • Wash your hands fully with soap and water after cleanup.

What you need

  • Go Direct Gas Pressure Sensor1 per group
  • Vernier Stir Station and stir bar1 per group
  • Two-hole rubber stopper with valve and tubing1 set
  • 125 mL Erlenmeyer flask and clamp1
  • 25 mL and 50 mL graduated cylinders1 each
  • Digital balance (0.01 g precision)1 per station
  • Limestone or marble chips4 to 6 chips (about 3 g total)
  • 6.0 M Hydrochloric acid solution10 mL per group · teacher
  • 6.0 M Sulfuric acid solution10 mL per group · teacher
  • Distilled water wash bottle1 bottle
  • Tablet running Graphical Analysis1
  • Splash goggles and nitrile gloves1 set per person
Student weighing marble chips on a digital balance

Step 1 of 11

Weigh your marble chips

  1. Select one or two clean limestone or marble chips with a total mass of 1.00 to 1.50 g.
  2. Place them on the digital balance. Record the exact mass in your notebook.
  3. Keep this chip set ready on a clean watch glass for Run 1.
Stop and check
  • The balance shows zero before you place chips on it.
  • Chips are dry and clean.
  • Gloves and goggles are on.

Careful: Heavy chips can damage the sensor if they fall onto a delicate balance pan. Place chips gently onto the centre of the pan with forceps.

Student pouring 40 mL of distilled water into an Erlenmeyer flask

Step 2 of 11

Measure distilled water into the flask

  1. Use the 50 mL graduated cylinder to measure exactly 40 mL of distilled water.
  2. Pour the water into your clean 125 mL Erlenmeyer flask.
  3. Gently slide in a small magnetic stir bar.
Stop and check
  • Graduated cylinder is clean.
  • Flask has no cracks.
  • Reading meniscus at eye level.

Careful: A magnetic bar can crack the glass flask bottom if it falls from high. Tilt the flask slightly and let the stir bar slide down gently.

125 mL flask clamped to the Stir Station rod with spinning stir bar

Step 3 of 11

Clamp flask on the Stir Station

  1. Place the flask on the centre of the Vernier Stir Station platform.
  2. Attach the utility clamp to the rod and secure the flask neck firmly.
  3. Turn the stir knob to a smooth, slow speed so the liquid does not splash.
Stop and check
  • The clamp holds the flask firmly and does not crush the glass.
  • Flask sits flat against the platform.
  • The stir bar spins smoothly and does not bounce.
  • Note the knob position so you can match this speed in every run.

Careful: If you tighten the metal clamp too much, you can crush the flask neck. Tighten the clamp screw until snug, then stop. Never force it.

Teacher pouring acid into the clamped flask

Step 4 of 11 Teacher does this

Adult adds hydrochloric acid

  1. The teacher measures 10 mL of 6.0 M HCl in a 25 mL graduated cylinder.
  2. The teacher carefully pours the acid into the flask with the 40 mL water.
  3. Stand one step back while the teacher adds the acid. The mixture warms slightly.
Stop and check
  • Teacher wears purple chemical-resistant gloves, apron, and eye protection.
  • Acid is always added to water, never water to concentrated acid.
  • Students keep hands back.

Careful: 6.0 M HCl causes chemical burns to skin and eyes. Fumes irritate lungs. Only the adult dispenses the acid. Pour down the inside glass wall slowly.

Student connecting plastic tubing to the Gas Pressure Sensor port

Step 5 of 11

Attach tubing and check the seal

  1. Connect the plastic tube from the rubber stopper assembly to the Gas Pressure Sensor.
  2. Turn the Luer-lock connector about one-half turn until it is snug.
Stop and check
  • The tube has no kinks or cracks.
  • The Luer-lock connector has correct threads.
  • Valve is fully closed.
  • Small blue shutoff valve on the stopper is in the closed position (crosswise).
  • Do not put the stopper in the flask yet.

Careful: Cross threads on the plastic Luer connector can strip the threads and cause a pressure leak. Line up the connector straight and turn gently half a turn.

6 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

Cambridge AS & A Level
  • Direct Level AS & A Level, Chemistry, chapter 3: Atoms, molecules and stoichiometry
  • Direct Level AS & A Level, Chemistry, chapter 9: Rates of reaction

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.