Experiments › Human Physiology
Why is balancing hard in the dark?
Balance
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why do you immediately start swaying when you close your eyes on one foot?
Show the answer
Your brain uses your eyes like a steady camera tripod. Shut them, and your body must make fast wobble corrections that our sensor can track.

Introduction
Why Is Balancing Hard in the Dark?
Stand on one foot right now. Easy, right? Now close your eyes. Within two seconds, your ankle starts twitching and your body wobbles. Why does that happen? Your brain balances using three helpers: your eyes, your inner ear, and sensors in your muscles. When you turn off your eyes, your brain has to work three times harder. Today, you will measure these secret wobbles with an acceleration sensor.
Driving question: Why is it so much harder to stay balanced when you close your eyes?
What you will learn
Today you will find out
- I can explain how eyes and body sensors work together to keep us balanced.
- I can measure how much my body wobbles when my eyes are open compared to closed.
- I can compare wobble numbers between two feet and one foot to see which is more stable.
- I can act as an alert spotter to protect my lab partner from tripping or falling.
- I can explain how training improves balance in sports and daily activities.
Why it matters: Tightrope walkers, footballers, and doctors checking concussions all study balance reflexes. Today you test yours like a physiologist.
Safety first
Scientist Rules for Today
- Always have a spotter stand within arm's reach of the subject.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Clear all chairs, bags, and sharp desk corners at least 2 metres away.
- If the subject feels dizzy or starts to fall, open eyes. Put both feet down immediately.
- Never push, startle, or distract the person who balances.
- Do not do the balance test if you have an injured foot or an ear infection.
What you need
- Go Direct Force and Acceleration Sensor1
- Tablet running Graphical Analysis1
- roll of tape1 roll
- protective lab gloves1 pair per student

Step 1 of 6
Set up sensor channels and collection mode
- Turn on the sensor. Connect the sensor to your tablet in Graphical Analysis.
- In Sensor Channels, uncheck default Force, check X-axis acceleration, and tap Done.
- Tap Mode. Set Rate to 100 samples/s and End Collection to 30 s. Tap Done.
- Tablet Bluetooth is turned on.
- Sensor power LED glows green.
- Hands are clean and dry.
Careful: If you leave Force selected, the graph shows zero movement instead of acceleration wobbles. Confirm the channel shows 'X-axis acceleration (m/s²)' on your graph axis.

Step 2 of 6
Place the sensor in your pocket
- The subject slips the sensor into a front trouser pocket.
- Point the metal hook straight up.
- Make sure the sensor sits snugly so it does not bounce loose.
- Stick a small piece of coloured tape on the wall at eye level as your focus target.
- The sensor hook points up.
- The sensor stays still against the thigh.
- The floor space has no backpacks or chairs nearby.
Careful: A loose sensor that slides in a baggy pocket records cloth friction instead of true body sway. Press the sensor snug against the hip. Use a strip of tape if the pocket is loose.

Step 3 of 6
Test balance on both feet
- The subject stands firmly on both feet and stares at the wall tape dot.
- The spotter stands ready with hands poised near the subject's waist.
- Tap Collect to begin.
- At exactly 10 seconds, call out 'Eyes closed!' The subject closes eyes until 30 seconds.
- Spotter is focused and within arm's reach.
- The subject looks at the wall, not at the tablet.
- The tablet operator watches the clock counter.
Careful: The subject can sway unexpectedly and lose balance when they close their eyes. Hold your hands at hip level. Brace the subject immediately if needed.

Step 4 of 6
Measure wobble size with statistics
- Drag across the 0 to 10 s region (eyes open) on the graph to highlight it.
- Tap Graph Tools and choose View Statistics.
- Write down the Delta y (Δy) value in Table 1.
- Now highlight 10 to 30 s (eyes closed), view statistics, and record Delta y.
- The full 30 seconds of data were collected.
- The two regions (0-10 s and 10-30 s) are selected separately.
Careful: If you highlight across the 10-second transition line, you mix open and closed eyes data. Stop your first selection box neatly before the 10-second mark.

Step 5 of 6
Test balance on your left foot
- Put the sensor in the left front pocket. Make sure the hook points up.
- The subject stands on the left foot and raises the right foot 10 cm off the floor.
- Tap Collect. Stare at the wall target for 10 seconds.
- At 10 seconds, close your eyes. Keep your balance until 30 seconds or until your foot touches down.
- Spotter is fully alert with both hands ready at hip height.
- Subject balances on a level, dry floor.
- If the subject loses balance, put the right foot down immediately.
Careful: A balance test on one foot with eyes closed causes strong, sudden wobbles. Spotter stays glued to the subject. Step down instantly if you start to fall.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 10, Biology, chapter 10: The Nervous System and Sense Organs
- Direct Level DP, Sports, Exercise and Health Science, chapter 5: Skill in Sports
Versions and what each needs
- Why is balancing hard in the dark?
Human Physiology, 50 min, Based on a Vernier lab
Needs: Go Direct Force and Acceleration Sensor