Experiments › Biology

Why is breathing harder in asthma?

Airflow Resistance and Lung Volumes

Grades 7-8Biology1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

Two drinking straws, one wide smoothie straw and one tiny pinched coffee stirrer straw

Wonder

Why does drinking a thick milkshake through a skinny straw take so much effort?

Show the answer

A skinny straw resists fluid flow. During asthma, airways swell up just like a pinched straw. Today, you will measure how narrow breathing pipes change airflow speed and lung capacity.

An athlete resting with hands on knees after a sprint in the park

Introduction

Why Is Breathing Harder in Asthma?

Millions of people live with asthma. During an asthma attack, the bronchial airways swell, tighten up, and clog with sticky mucus. Breathing suddenly feels like trying to run while breathing through a tiny straw! In this investigation, you will use a Go Direct Spirometer to measure how much air your lungs move and how fast it rushes out. Then, by safely restricting airflow with a barrier, you will discover how narrowed tubes alter your breathing curve.

Driving question: Why does a narrowed airway make each breath feel like hard work?

What you will learn

What You Will Discover

  • I can measure normal breath volume and deep breath capacity using a spirometer.
  • I can explain why swollen airways slow down air movement during an asthma attack.
  • I can compare graphs to show how a narrowed airway changes breathing patterns.
  • I can assemble and use the spirometer safely without sharing mouthpieces.
  • I can connect flow rate tests to real-world asthma monitors and doctor visits.

Why it matters: Doctors use spirometry tests to check lung health, diagnose asthma, and test how well inhalers help patients breathe freely.

Safety first

Hygiene and Comfort Rules

  • Never share mouthpieces or bacterial filters. Every student volunteer must have their own unused set.
  • Do not volunteer if you currently have a cold, cough, asthma flare-up, or feel dizzy.
  • Sit comfortably with your arm braced on a sturdy table during all breath tests.
  • Stop immediately if you feel lightheaded, out of breath, or tired.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • This lab helps you learn science. Never use it to diagnose medical health.

What you need

  • Go Direct Spirometer1
  • Disposable Bacterial Filters for Spirometer1 per volunteer
  • Disposable Mouthpieces for Spirometer1 per volunteer
  • Noseclips for Spirometer1 per volunteer
  • roll of tape1 roll
  • pencil1 ballpoint pen or sharp pencil
  • Tablet running Graphical Analysis1
Student hands pushing bacterial filter and cardboard mouthpiece into the spirometer flow head

Step 1 of 9

Assemble the breathing channel

  1. Take a fresh bacterial filter from the package.
  2. Push the larger diameter side of the filter firmly into the 'Inlet' side of the spirometer flow head.
  3. Slide your clean cardboard mouthpiece onto the outer stem of the filter.
  4. Make sure the pieces fit snug and airtight so air cannot leak around the rim.
Stop and check
  • The filter and mouthpiece are brand new and unused.
  • Hands are clean and dry.

Careful: Do not share mouthpieces. Mouthpieces that you share can spread germs and viruses between students. Only use your own mouthpiece and filter. Never swap with a classmate.

Spirometer on table next to tablet showing green Bluetooth connection

Step 2 of 9

Power on and pair your sensor

  1. Press the power button on your Go Direct Spirometer.
  2. Open Vernier Graphical Analysis on your tablet.
  3. Tap Sensor Data Collection. Select your spirometer from the list.
  4. The LED light on the handle will glow steady green once Bluetooth connects.
Stop and check
  • Tablet Bluetooth is enabled.
  • The sensor battery is charged.

Careful: If you pair to a nearby sensor, you record data from a different student. Match the 8-digit sensor ID on the sensor handle with the screen.

Gloved hands holding the spirometer vertically with elbows braced on a table

Step 3 of 9

Hold upright, steady, and zero the sensor

  1. The subject sits comfortably in a chair with both elbows braced firmly against the lab table.
  2. Hold the spirometer handle vertical. Point the mouthpiece toward your face.
  3. Do not breathe into the mouthpiece yet. Keep the sensor completely still.
  4. Your partner taps the Flow Rate meter on the tablet and selects Zero.
Stop and check
  • Subject is seated with elbows firmly braced.
  • The sensor is held perfectly vertical and motionless.
  • Nobody blows into the sensor.

Careful: Sensor movement or tilt during zero calibration causes large false airflow readings. Keep the handle straight up and down. Rest elbows on the table so your hands do not shake.

Subject holding spirometer with nose clip in place while partner watches tablet graph grow

Step 4 of 9

Record normal unobstructed breathing

  1. Have your partner tap Collect on your inhale as you breathe normally and quietly for 4 full cycles.
  2. After the 4th cycle, take the deepest inhale possible, then immediately blast out all the air until completely empty.
  3. Breathe normally for 2 recovery breaths. Then tap Stop.
Stop and check
  • The nose clip is firmly in place and holds the nostrils closed.
  • Lips form a tight seal around the cardboard mouthpiece.
  • Subject feels relaxed and comfortable.
  • 1. The subject puts on the nose clip so air can only pass through the mouth.
  • 2. Place the cardboard mouthpiece in your mouth and seal your lips tightly around it.

Careful: Air leaks around the lips or nose cause lung volume numbers to be too small. Keep a firm lip seal throughout the entire test. Never remove the nose clip early.

Tablet screen with shaded statistics box measuring peak to valley height

Step 5 of 9

Find normal Tidal Volume and Vital Capacity

  1. Tap Graph Tools and choose View Statistics.
  2. To find Tidal Volume (TV): drag your finger across one normal quiet breath from peak to valley. Record the Δy value in Table 1.
  3. To find Vital Capacity (VC): drag from the peak of your deep breath to the lowest valley.
  4. Record the Δy value as Vital Capacity (VC). In healthy teens, this is usually 3.0 to 4.5 litres.
Stop and check
  • The graph clearly shows 4 small waves and 1 large mountain.
  • The statistics box is visible on screen.

Careful: A peak-to-baseline measurement gives a total breath volume that is too low. Always measure peak-to-valley. Always select from the top peak all the way to the lowest valley that immediately follows.

4 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 11, Biology, chapter 14: Breathing and Exchange of Gases
ICSE (CISCE)
  • Direct Class 7, Biology, chapter 7: Allergy
IB Diploma
  • Related Level DP, Biology, chapter B3.1: Gas Exchange

Versions and what each needs

  • Why is breathing harder in asthma?
    Human Physiology Vol 2, 60 min, Based on a Vernier lab
    Needs: Go Direct Spirometer

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.