Experiments › Chemistry
Why is vinegar sour yet safe?
Half Titration
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does salad vinegar taste sharp but stay safe to eat?
Show the answer
Vinegar is a weak acid that holds onto its sour particles tightly. Scientists measure this natural strength with a score called pKa, and today you will uncover it.

Introduction
The Halfway Secret of Vinegar
Vinegar tastes sharp because it contains acetic acid. Some acids are fierce like battery acid, while others are gentle like vinegar. How do chemists score an acid's natural strength? You might think you must neutralize every single drop. But today, you will use a clever chemical shortcut. By cancelling out exactly half of your acid and mixing it with the other half, the pH lands on a magic number: the acid's true strength score!
Driving question: Can balancing half of an acid reveal its hidden strength score?
What you will learn
Today you will discover
- I can tell when an acid is cancelled out by looking at indicator colour and pH.
- I can explain how the halfway balance reveals an acid's natural strength score.
- I can help run a precise titration setup using sensor probeware safely.
- I can read the halfway pH value and identify it as the acid's strength score.
- I can name real-world systems where balanced acid-base mixtures keep pH steady.
Why it matters: From making tangy cheeses to keeping human blood at a safe pH, balanced acid mixtures protect living things every second.
Safety first
Scientist Rules for Today
- Wear splash goggles and chemical-resistant gloves at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- 1.0 M sodium hydroxide and 1.0 M acetic acid can cause skin burns and eye damage.
- Only your teacher pours, fills burets, or handles bulk stock chemicals.
- Never taste or sniff any lab solution. Acetic acid fumes are pungent.
- Phenolphthalein indicator is flammable. Keep it away from hot surfaces.
- Keep all liquids safely away from your tablet. Wash hands with soap at the end.
What you need
- Go Direct pH Sensor1 per group
- Stir Station1 per group
- magnetic stir bar1 per group
- Electrode Support1 per group
- buret1 (50 mL) · teacher
- buret clamp1 per group · teacher
- 250 mL beaker1 per group
- clear solution in a reagent bottle60 mL (1.00 M acetic acid) · teacher
- clear solution in a reagent bottle50 mL (1.00 M sodium hydroxide) · teacher
- red or pink liquid in a reagent bottle1 dropper bottle (phenolphthalein)
- Plastic Beral pipets2 per group
- Distilled water wash bottle1 per group
- Splash goggles and nitrile gloves1 set per person

Step 1 of 6 Teacher does this
Teacher fills the buret and dispenses 25 mL
- Put on goggles and gloves.
- Your teacher clamps the 50 mL buret to the Stir Station support rod.
- The teacher fills the buret with 1.00 M acetic acid to the 0.0 mL line.
- The teacher carefully drains precisely 25.0 mL of acid into your 250 mL beaker.
- Notice that exactly 25.0 mL of acid remains inside the buret for later!
- Everyone has safety goggles and gloves on.
- The buret clamp holds the glass buret firmly vertical.
- Students stand one step back while a person pours chemicals.
Careful: 1.00 M acetic acid can splash or cause painful skin irritation. Only the teacher pours acid into the buret. Keep a wash bottle ready.

Step 2 of 6
Save an emergency acid pipet and add indicator
- Squeeze a plastic Beral pipet and draw up a small amount of acid from your beaker.
- Fill the pipet bulb about 1/4 full. Set this pipet safely aside on a paper towel.
- This reserve acid is your safety net in case you add too much base later!
- Now add 1 to 2 drops of phenolphthalein indicator to the beaker.
- Swirl gently. The liquid stays completely clear in acid.
- Gloves and goggles are on your hands and eyes.
- Paper towel is ready to rest the acid pipet on.
- The reserve pipet is placed away from the edge.
Careful: If you drop the pipet, acid droplets can splash on skin or clothes. Squeeze the bulb gently. Place the pipet bulb-down on a clean paper towel.

Step 3 of 6
Set up the Stir Station and pH Sensor
- Place your beaker onto the centre of the Stir Station platform.
- Clamp the Go Direct pH Sensor into the Electrode Support on the rod.
- Turn the Stir Station control knob clockwise until the stir bar spins smoothly at a gentle pace.
- The pH sensor bulb is kept wet and rinsed.
- The sensor clamp is tightened securely.
- The sensor tip does not touch the stir bar.
- Gently slide the magnetic stir bar down the beaker wall so it rests at the bottom.
- Unscrew the storage bottle from the Go Direct pH Sensor and rinse the glass bulb with distilled water.
- The sensor tip is fully submerged, well away from the stir bar.
Careful: The stir bar can strike and shatter the delicate glass bulb of the pH sensor when it turns. Position the sensor probe near the side wall. Leave space for the stir bar in the middle.

Step 4 of 6
Add base until you reach the faint pink turning point
- Your teacher supplies about 50 mL of 1.00 M sodium hydroxide (NaOH) in a small beaker.
- Take a fresh plastic pipet and draw up some NaOH solution.
- Stir gently. Add NaOH about 1 mL at a time to the acetic acid beaker.
- Watch the live pH meter rise. When it reaches around pH 6, SLOW DOWN.
- Add NaOH drop by single drop. Stop when the liquid flashes pink and stays faint pale pink (pH ~8.7).
- If the colour turns dark magenta (overshot), add drops from your reserve acid pipet until clear. Then add one drop of NaOH.
- Goggles are securely over everyone's eyes.
- The stir bar turns gently and does not splash.
- You have the reserve acid pipet ready in case you overshoot.
Careful: If you add base too fast, you will pass the target point into dark purple and spoil the exact balance. Add drop by drop near pH 6. Aim for the faintest pink colour that stays for 30 seconds.

Step 5 of 6 Teacher does this
Pour in the remaining 25 mL of raw acid
- Congratulations: you have completely neutralised the first 25.0 mL of acid!
- Now look up at the buret. Exactly 25.0 mL of fresh unreacted acetic acid is still inside.
- Open the buret stopcock completely and drain all 25.0 mL into your beaker.
- Watch what happens to the pink colour as the fresh acid rushes in: it vanishes instantly!
- Let the Stir Station turn smoothly to mix the two halves fully.
- The buret tip is positioned directly over the beaker mouth.
- The beaker does not overflow (plenty of room for 25 mL).
- The teacher supervises as the buret drains.
Careful: If the liquid drains too fast, acid can splash over the beaker rim. Open the stopcock steadily. Make sure that the stream lands inside the beaker.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 12, Chemistry, chapter 3: Aldehydes, Ketones and Carboxylic Acids
Versions and what each needs
- Why is vinegar sour yet safe?
Advanced Chemistry, 50 min, Based on a Vernier lab
Needs: Go Direct pH Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.