Experiments › Chemistry
Why salt an icy road?
Freeze Pt
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why do snowploughs sprinkle salt on freezing winter roads?
Show the answer
Salt dissolved in water pushes the freezing point below zero. The water stays liquid even in freezing air. Today you will measure this freezing drop yourself!

Introduction
Why Salt an Icy Road?
When winter roads freeze over, workers spread rock salt to melt the slick ice. Pure water locks into solid ice at 0°C. Adding salt dissolves particles that crowd the liquid and block ice crystals from forming. The mixture must get even colder to freeze solid. Scientists call this freezing-point depression. Today, you will measure how dissolved particles push a liquid's freezing point lower.
Driving question: Why does adding dissolved particles stop a liquid from freezing at its normal temperature?
What you will learn
Today you will find out
- I can find the freezing temperature on a cooling curve.
- I can explain how dissolved particles lower the freezing point.
- I can compare two graphs to measure how much the freezing point dropped.
- I can safely collect temperature data as a liquid freezes.
- I can explain why salt is spread on icy winter roads.
Why it matters: Car radiators, ice cream makers, and winter road crews rely on freezing point drops every single day.
Safety first
Scientist Rules for Today
- Wear safety goggles and lab gloves throughout the experiment.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Hot water and melted acid can cause burns. The teacher handles hot tubes from the hot water bath.
- Never pull or twist the temperature probe if the acid hardens around it.
- Keep hands and faces away from chemical tubes; never taste or inhale lab chemicals.
- Wash hands with soap and water after cleanup.
What you need
- Go Direct Temperature Probe1
- Stir Station1
- utility clamp1
- 400 mL beaker1
- two 18 × 150 mm test tubes2 tubes (Tube A pure lauric acid, Tube B mixture) · teacher
- Tablet running Graphical Analysis1
- Splash goggles and nitrile gloves1 set per student
- tissue or paper towels1 pack

Step 1 of 9
Set up the cooling water bath
- Add about 300 mL of room-temperature tap water (20 to 25°C) to your 400 mL beaker.
- Place the beaker onto the base of the Stir Station.
- Attach the utility clamp to the upright rod so it hangs above the beaker.
- The Stir Station sits flat and steady on the lab bench.
- The beaker contains water at room temperature, not hot water.
Careful: Glass beaker can tip if the clamp thumbscrew hits it. Position the clamp rod away from the beaker lip before you tighten it.

Step 2 of 9
Connect the temperature probe
- Press the power button on the Go Direct Temperature Probe.
- Open Graphical Analysis on your tablet. Connect to the probe over Bluetooth.
- Check that the sensor light flashes green and the screen shows live temperature.
- Tablet Bluetooth is turned on.
- The temperature probe battery is charged.
Careful: Sensor pairs with another group's tablet nearby. Check the sensor ID printed on your probe before you tap Connect.

Step 3 of 9 Teacher does this
Adult brings the hot melted lauric acid
- An adult removes Tube A (pure melted lauric acid) from the hot water bath.
- The adult fastens the utility clamp around the top of the test tube.
- Position the tube directly above your cool water beaker. Do not touch the hot glass!
- The adult wears heat-resistant purple gloves and goggles.
- The test tube clamp is secure at the top neck of the tube.
- Students keep hands back while hot tube is positioned.
Careful: Hot glass tube can slip and cause burns or skin irritation if touched directly. Only the adult handles the hot tube. Clamp tightly at the very top of the tube.

Step 4 of 9 Teacher does this
Insert probe and lower into the cooling bath
- Insert the stainless steel probe into the melted acid.
- Tap Collect on your tablet to start data collection.
- Lower the clamped test tube into the cool water beaker. Make sure that the beaker water level is higher than the acid inside.
- The probe tip rests in the liquid acid and does not touch the tube bottom.
- The beaker water level is higher than the liquid inside the tube.
- Make sure the water outside is higher than the acid level inside.
Careful: If the water outside is too low, the acid will cool unevenly. Adjust the clamp height so the cool water covers the entire liquid volume.

Step 5 of 9
Stir gently and record pure acid freezing
- Gently move the probe up and down by about one centimetre.
- Stir continuously for the full 10 minutes.
- Watch the acid turn cloudy and solid as crystals lock together.
- Stir with small, gentle up-and-down motions.
- Do not tap or bang the probe against the bottom of the glass tube.
Careful: If you stir vigorously, you can crack the glass test tube. Use a light two-finger pinch on the probe handle; move slowly up and down.
4 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 12, Chemistry, chapter 1: Solutions
Versions and what each needs
- Why salt an icy road?
Advanced Chemistry, 50 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.