Experiments › Physical Science
Why wait for a thermometer?
Temp Response
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why must you keep a thermometer under your tongue for three whole minutes?
Show the answer
A thermometer measures its own temperature, not yours! Heat takes time to flow into the metal tip until both match. Today you measure this response time.

Introduction
Why Wait for a Thermometer?
When you feel sick, your parents place a thermometer under your tongue. They make you wait three minutes before reading it. Why cannot it give the number instantly? A sensor cannot read your body until heat flows into it. That delay is called response time. Today, you will plunge a digital probe from ice water into hot water. You will watch the temperature climb on a live graph and calculate the exact response time.
Driving question: Why do you have to wait several minutes before reading an oral thermometer?
What you will learn
Today you will find out
- I can explain why a thermometer needs time to reach a steady temperature reading.
- I can set up and record live temperature data over time with a digital probe.
- I can identify the independent and dependent variables on my graph axes.
- I can calculate the response time of the probe using data points from my graph.
- I can describe factors that make temperature sensors respond faster or slower.
Why it matters: Meteorologists, oven designers, and doctors all rely on fast, accurate temperature readings. Understanding sensor lag keeps people safe.
Safety first
Lab Rules for Hot and Cold Liquids
- Hot water at 70 deg C can cause painful scalds. An adult heats and pours all hot water.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Never carry beakers filled with hot water across the room.
- Hold the temperature probe by its plastic handle, never by the metal shaft after hot water.
- Glass beakers can crack if knocked. Keep them in the centre of your table.
- Keep all water at least 30 cm away from your tablet or laptop.
- Wash your hands with soap and water after you clean up.
What you need
- Go Direct Temperature Probe1
- Tablet running Graphical Analysis1
- 250 mL beaker2
- ice cubes3 to 4 cubes
- hot water150 mL (70 deg C) · teacher
- laboratory hot plate1 per class · teacher
- paper towelseveral sheets

Step 1 of 6
Prepare the cold water bath
- Pour about 100 mL of room temperature tap water into your first 250 mL beaker.
- Add two or three ice cubes to the beaker.
- Swirl gently so the water cools down to between 0 deg C and 10 deg C.
- The beaker sits flat on the table, away from table edges.
- Hands are dry before you touch electronic devices later.
Careful: Ice cubes that drop into a glass beaker too hard can chip or crack the glass bottom. Slide ice cubes gently down the inner glass wall of the beaker.

Step 2 of 6
Connect your Temperature Probe
- Press the power button on your Go Direct Temperature Probe once.
- Open Graphical Analysis on your device.
- Select Sensor Data Collection. Connect your probe with Bluetooth.
- Tablet is placed at least 30 cm away from water beakers.
- Bluetooth is turned on on your tablet or computer.
- Confirm the live reading shows on screen.
Careful: Water that drips from hands onto the tablet screen or keyboard can cause damage. Dry your hands on paper towels before you touch your tablet screen.

Step 3 of 6 Teacher does this
Adult supplies the hot water
- Have an adult pour about 150 mL of hot water (about 70 deg C) into your second 250 mL beaker.
- Place the hot water beaker right next to your cold water beaker.
- Do not move the hot beaker once it is on your bench.
- The adult wears heat-resistant purple gloves.
- Students keep their hands flat on the table, away from the beaker.
- The bench surface is completely clear of clutter.
Careful: Hot water at 70 deg C can cause immediate skin burns if spilled or splashed. Only the adult pours the hot water. Keep your hands back until the adult finishes.

Step 4 of 6
Position the probe in the cold water
- Hold the probe by its black plastic handle.
- Lower the metal shaft into the cold water beaker and stir briefly for 5 seconds.
- Rest the probe upright in the beaker, as shown in the manual diagram.
- The probe tip is submerged in the cold water.
- The probe does not tap forcefully against the bottom glass.
- Do not stir or swirl the water any further.
Careful: The probe cable or handle can knock the beaker over. Support the probe handle gently with your hand or rest it steadily against the spout.

Step 5 of 6
Start data collection in cold water
- When your team is ready, tap Collect in Graphical Analysis.
- Watch the graph plot a flat line at the cold water temperature for the first 20 seconds.
- Keep your eyes on the clock in the app as it approaches 20 seconds.
- Both beakers are side by side so movement between them is quick and smooth.
- One team member tracks the timer.
- Do not stir or move the water or probe.
Careful: An accidental bump to the table can shake the beakers. Keep hands steady on the table and watch the timer count up.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 6, Science, chapter 7: Temperature and its Measurement
- Related Class 6, Physics, chapter 4: Temperature and its Measurement
- Direct Class 7, Physics, chapter 11: Temperature and Its Measurement
- Related Level AS & A Level, Physics, chapter 14: Temperature
Versions and what each needs
- Why wait for a thermometer?
Physical Science, 45 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe