Sensors › Environment and water quality

Go Direct Chloride Ion-Selective Electrode

GDX-CLEnvironment

Chloride ion concentration in water

An ion-selective electrode joined to a wireless Go Direct amplifier, used to measure chloride ion (Cl-) concentration in water samples in mg/L, which also serves as an indicator of salinity. The electrode is a gel-filled combination type with a solid-state membrane, so it has no membrane module to replace, and it comes with high and low standards for calibration. Vernier does not recommend it below high school level because results depend on careful technique.

Type: wireless ISE (Go Direct ISE Amplifier with Chloride ISE BNC electrode)

Price on requestWe quote for the full set your lab needs, with training and support.

What students do with it

  • Measure chloride in freshwater, brackish and sea water
  • Estimate salinity from chloride concentration
  • Determine salt content of food samples
  • Practise two-point calibration with standards
  • Relate electrode potential to concentration (Nernst equation)

What it records

  • Chloride (mg/L as Cl⁻)
  • mV (raw electrode potential)

What is in the box

  • Go Direct ISE Amplifier connected to a Go Direct Chloride ISE BNC electrode
  • 30 mL High Standard solution with SDS (1000 mg/L Cl-)
  • 30 mL Low Standard solution with SDS (10 mg/L Cl-)
  • Short-Term ISE Soaking Bottle
  • Polishing strip
  • Micro USB cable

What else you need

  • A computer, Chromebook, iOS or Android device, or a LabQuest 2 or LabQuest 3 (not the original LabQuest)
  • Vernier Graphical Analysis app (computer, Chromebook web app, iOS or Android)
  • USB power source for charging (charge at least 2 hours before first use)
  • Soak the electrode tip in the High Standard for 30 minutes before use
  • Distilled water for rinsing

Accessories and replacement parts

  • Standard Cl ISE Solution, High, 1000 mg/L (500 mL) CL-HST
  • Standard Cl ISE Solution, Low, 10 mg/L (500 mL) CL-LST
  • Electrode Storage Bottles (pack of 5) BTL-ES
  • Go Direct Chloride ISE BNC electrode GDX-CL-BNC
  • Go Direct ISE Amplifier GDX-ISEA
  • Go Direct Nitrate ISE BNC GDX-NO3-BNC
  • Go Direct Ammonium ISE BNC GDX-NH4-BNC
  • Go Direct Calcium ISE BNC GDX-CA-BNC
  • Go Direct Potassium ISE BNC GDX-K-BNC
  • Go Direct Charge Station GDX-CRG
  • Go Direct Sensor Clamp GDX-CLAMP
  • Micro USB Cable CB-USB-MICRO
  • USB-C to Micro USB Cable CB-USB-C-MICRO
  • Go Direct 300 mAh Replacement Battery GDX-BAT-300

Care and limits

  • Two-point calibration with the High and Low Standards is recommended; a factory calibration is stored on the sensor
  • Polish the solid-state membrane with the polishing strip when response becomes slow
  • Do not soak for more than 24 hours; store long term in the storage bottle with a damp sponge
  • Never immerse above the BNC junction; the amplifier is not water resistant

Specifications are as published by Vernier, checked on 18 November 2026. Descriptions are written by Stemious. Vernier products are designed for education and are not for medical, industrial or research-grade commercial use. Vernier and Go Direct are trademarks of Vernier Science Education.

With Stemious in India

1 experiment in the Stemious appEach one runs step by step with this sensor: read it first, then do it with live data, photos and notes.
Mapped to your boardUsed in chapters of IB (1 chapter).
Supplied and supported hereStemious is Vernier's partner in India: quote, delivery, setup and teacher support from Pune.

School experiments that use it