Go Direct Electrode Amplifier
Amplifies signals from ion-selective electrodes and other electrochemical sensors
The Go Direct Electrode Amplifier is a wireless mV and pH amplifier with a BNC socket. Any compatible BNC electrode, such as a pH, flat pH, ORP or ion-selective electrode from Vernier or another maker, plugs into it and is read as pH or millivolts. One amplifier can serve several electrode types, and a worn electrode can be replaced without replacing the electronics.
Type: wireless amplifier for BNC electrodes (Bluetooth + USB, rechargeable)
What students do with it
- Measure pH with a BNC pH electrode
- Measure redox potential with an ORP electrode
- Read ion-selective electrodes in mV
- Follow acid-base or potentiometric titrations
- Reuse existing third-party BNC electrodes with Go Direct software
What it records
- Potential (mV)
- pH
What is in the box
- Go Direct Electrode Amplifier
- Micro USB cable
What else you need
- A BNC electrode (pH, ORP or ion-selective), not included
- A computer, Chromebook, or iOS or Android device running the Vernier Graphical Analysis app (connect by Bluetooth or USB; no interface needed)
- Optional: LabQuest 3 or LabQuest 2 as a standalone interface (the original LabQuest is not compatible)
- pH buffer solutions if a pH calibration is wanted
Accessories and replacement parts
- Electrode Support ESUP
- Go Direct Charge Station GDX-CRG
- Go Direct pH BNC Electrode GDX-PH-BNC
- Go Direct Flat pH BNC Electrode GDX-FPH-BNC
- Go Direct Glass-Body pH BNC Electrode GDX-GPH-BNC
- Go Direct ORP BNC Electrode GDX-ORP-BNC
- Go Direct Potassium Ion-Selective Electrode BNC GDX-K-BNC
- Go Direct Nitrate Ion-Selective Electrode BNC GDX-NO3-BNC
- Go Direct Ammonium Ion-Selective Electrode BNC GDX-NH4-BNC
- Go Direct Chloride Ion-Selective Electrode BNC GDX-CL-BNC
- Go Direct Calcium Ion-Selective Electrode BNC GDX-CA-BNC
- Micro USB Cable CB-USB-MICRO
- Micro USB to USB-C Cable CB-USB-C-MICRO
- Go Direct 300 mAh Replacement Battery GDX-BAT-300
Care and limits
- A two-point pH calibration with buffers gives the most accurate results; calibration is stored on the amplifier
- Calibration is not needed, and is disabled, when reading mV from ORP or ion-selective electrodes
- Keep away from sources of electrical noise such as motors, monitors and microwaves
- Not water resistant; never immerse the unit
Specifications are as published by Vernier, checked on 18 November 2026. Descriptions are written by Stemious. Vernier products are designed for education and are not for medical, industrial or research-grade commercial use. Vernier and Go Direct are trademarks of Vernier Science Education.