Sensors › Chemistry

Go Direct Mini GC

GDX-GCChemistry

Separation and identification of volatile compounds using gas chromatography

A portable gas chromatograph for teaching, with a stainless steel capillary column and a carbon-nanotube chemiresistive detector that responds to polar and non-polar compounds. An internal pump uses room air as the carrier gas, so no gas cylinder is needed. It is controlled over Bluetooth or USB from the free Vernier Instrumental Analysis app.

Type: benchtop instrument (gas chromatograph; mains adapter; Bluetooth + USB)

Price on requestWe quote for the full set your lab needs, with training and support.

What students do with it

  • Separate and identify compounds in a volatile liquid mixture by retention time
  • Identify unknowns against known standards
  • Integrate peaks to compare relative amounts
  • Monitor the progress of a reaction
  • Analyse fractions from a distillation

What it records

  • Detector response (relative intensity)
  • Retention time (s)
  • Chromatogram (full run)

What is in the box

  • Go Direct Mini GC
  • Mini USB Cable
  • AC power supply
  • Hamilton syringe (1.0 µL)
  • Two extra septa (a third is already installed)
  • E-book: Chromatography Experiments with the Go Direct Mini GC (five investigations, download from Vernier account)
  • Carrying case

What else you need

  • Vernier Instrumental Analysis app (free) on a computer, Chromebook, iOS or Android device, or a LabQuest 2 or LabQuest 3 (original LabQuest is not compatible)
  • Mains power
  • Volatile liquid or headspace gas samples and rinse solvent such as acetone

Accessories and replacement parts

  • Mini GC 1 µL Hamilton Syringe GC-SYR-MIC
  • GC Septa (package of 4) GC-SEP
  • Replacement Power Supply for Vernier Mini Gas Chromatographs GC2-MINI-PS
  • Mini USB Cable CB-USB-MINI
  • USB-C to Mini USB Cable CB-USB-C-MINI

Care and limits

  • Never inject more than 0.6 µL of liquid; do not inject water, amines or other alkaline substances.
  • Replace the septum after about 150 injections; column and detector are not user replaceable.
  • Before storage, flush the column with 0.3 µL of acetone or n-hexane and purge for 15 minutes at 120°C and 20 kPa.
  • Use in a well-ventilated room away from flammable vapors. For educational use only; not intended for industrial, medical or commercial applications.

Specifications are as published by Vernier, checked on 18 November 2026. Descriptions are written by Stemious. Vernier products are designed for education and are not for medical, industrial or research-grade commercial use. Vernier and Go Direct are trademarks of Vernier Science Education.