Sensors › Chemistry
Go Direct Ion-Selective Electrode Amplifier
Amplifier for use with Vernier BNC ion-selective electrodes
A wireless amplifier with a BNC socket that accepts Vernier ion-selective electrodes and compatible third-party BNC electrodes. It reports electrode potential in mV or concentration in mg/L over Bluetooth or USB. One amplifier can serve several electrodes, and only the electrode needs replacing when its membrane wears out.
Type: wireless amplifier for BNC ISEs (Bluetooth + USB, rechargeable)
What students do with it
- Measure nitrate, ammonium, chloride, calcium or potassium ion concentration with the matching BNC electrode
- Carry out water quality surveys
- Practise two-point calibration with standard solutions
- Record raw electrode potential in mV
What it records
- Potential (mV)
- Chloride, Ammonium, Calcium, Nitrate or Potassium (mg/L), one at a time
What is in the box
- Go Direct Ion-Selective Electrode Amplifier
- Micro USB Cable
What else you need
- A BNC ion-selective electrode (sold separately)
- Standard solutions for calibration
- A computer, Chromebook, or iOS/Android device connected by Bluetooth or USB, or a LabQuest 2 or LabQuest 3
- Vernier Graphical Analysis app (or LabQuest App); NI LabVIEW also supported
Accessories and replacement parts
- Go Direct Nitrate Ion-Selective Electrode BNC GDX-NO3-BNC
- Go Direct Ammonium Ion-Selective Electrode BNC GDX-NH4-BNC
- Go Direct Chloride Ion-Selective Electrode BNC GDX-CL-BNC
- Go Direct Calcium Ion-Selective Electrode BNC GDX-CA-BNC
- Go Direct Potassium Ion-Selective Electrode BNC GDX-K-BNC
- Go Direct Charge Station GDX-CRG
- Micro USB Cable CB-USB-MICRO
- Go Direct 300 mAh Replacement Battery GDX-BAT-300
Care and limits
- A two-point calibration with High and Low standards is recommended; calibration is disabled in mV mode.
- Soak a new electrode in High Standard for 30 minutes before first use.
- The amplifier is not water resistant and must never be immersed.
- ISEs need careful technique; Vernier does not recommend them for elementary or middle school. For educational use only; not intended for industrial, medical or commercial applications.
Specifications are as published by Vernier, checked on 18 November 2026. Descriptions are written by Stemious. Vernier products are designed for education and are not for medical, industrial or research-grade commercial use. Vernier and Go Direct are trademarks of Vernier Science Education.
With Stemious in India
School experiments that use it
No school experiment in the catalogue uses it yet.