Sensors › Environment and water quality
Go Direct Potassium Ion-Selective Electrode BNC
Potassium ion concentration using BNC-connector electrode
The potassium ion-selective electrode on its own, ending in a BNC connector, for labs that already own a Go Direct Ion-Selective Electrode Amplifier. Plugged into the amplifier it measures K+ concentration in aqueous samples; the amplifier reads the potential in mV and works out the concentration. It is a gel-filled, non-refillable combination electrode whose PVC membrane module can be replaced when it wears out.
Type: wired electrode only (BNC); needs Go Direct ISE Amplifier GDX-ISEA
What students do with it
- Add potassium measurement to an existing Go Direct ISE Amplifier
- Measure potassium in water, soil-extract or runoff samples
- Swap between ion electrodes on one amplifier during water-quality surveys
- Calibrate with the supplied high and low standards
What it records
- Potassium Ion Concentration (mg/L)
- Voltage (mV)
What is in the box
- Go Direct Potassium ISE with BNC connector, packed with a storage bottle
- 30 mL High Standard solution with SDS (1000 mg/L K+)
- 30 mL Low Standard solution with SDS (10 mg/L K+)
- Short-Term ISE Soaking Bottle
What else you need
- Go Direct Ion-Selective Electrode Amplifier (GDX-ISEA), required
- A computer, Chromebook, LabQuest or mobile device running the data-collection software (Graphical Analysis), via the amplifier
- Distilled or deionized water for rinsing
- Optional ionic strength adjuster (1 M NaCl) for better accuracy at low concentrations
Accessories and replacement parts
- Go Direct Ion-Selective Electrode Amplifier GDX-ISEA
- Potassium Replacement Module K-MOD
- Potassium High Standard, 500 mL K-HST
- Potassium Low Standard, 500 mL K-LST
- Electrode Storage Bottles, pack of 5 BTL-ES
Care and limits
- Soak in High Standard for about 30 minutes before use (never more than 24 hours) and calibrate with the two standards
- Rinse and blot dry between samples; for storage beyond 24 hours keep in the storage bottle with a sponge moistened with distilled water
- Membrane module has a limited life and degrades on the shelf; do not stock replacements far ahead
- The BNC connection is not waterproof; do not submerge the whole electrode. Designed for educational use; not intended for industrial, medical or commercial applications
Specifications are as published by Vernier, checked on 18 November 2026. Descriptions are written by Stemious. Vernier products are designed for education and are not for medical, industrial or research-grade commercial use. Vernier and Go Direct are trademarks of Vernier Science Education.
With Stemious in India
School experiments that use it
No school experiment in the catalogue uses it yet.