Sensors › Environment and water quality

Go Direct Ammonium Ion-Selective Electrode

GDX-NH4Environment

Ammonium ion concentration in water

An ion-selective electrode joined to a wireless Go Direct amplifier, used to measure the concentration of ammonium ions (NH4+) in water samples. It ships with high and low standard solutions for a two-point calibration and reports directly in mg/L. The same amplifier accepts other Vernier ISE BNC electrodes.

Type: wireless ISE (Go Direct ISE Amplifier GDX-ISEA with Ammonium ISE BNC electrode)

Price on requestWe quote for the full set your lab needs, with training and support.

What students do with it

  • Measure ammonium in stream or pond water
  • Check for fertilizer runoff near fields
  • Compare water samples from different sites or seasons
  • Practise two-point calibration with standards
  • Relate electrode potential to concentration (Nernst equation)

What it records

  • Ammonium (mg/L)
  • Potential (mV)

What is in the box

  • Go Direct Ion-Selective Electrode Amplifier connected to a Go Direct Ammonium ISE BNC electrode
  • 30 mL High Standard solution with SDS (100 mg/L NH4+)
  • 30 mL Low Standard solution with SDS (1 mg/L NH4+)
  • Short-Term ISE Soaking Bottle
  • Micro USB cable

What else you need

  • A computer, Chromebook, iOS or Android device, or a LabQuest 2 or LabQuest 3 (not the original LabQuest)
  • Vernier Graphical Analysis app (computer, Chromebook web app, iOS or Android)
  • USB power source for charging (charge at least 2 hours before first use)
  • Soak the electrode tip in the High Standard for 30 minutes before use
  • Distilled water for rinsing

Accessories and replacement parts

  • Electrode Storage Bottles (pack of 5) BTL-ES
  • High NH4 ISE Standard Solution (500 mL) NH4-HST
  • Low NH4 ISE Standard Solution (500 mL) NH4-LST
  • Ammonium Replacement Membrane Module NH4-MOD
  • Go Direct Ammonium ISE BNC electrode GDX-NH4-BNC
  • Go Direct ISE Amplifier GDX-ISEA
  • Go Direct Charge Station GDX-CRG
  • Micro USB Cable CB-USB-MICRO
  • USB-C to Micro USB Cable CB-USB-C-MICRO
  • Go Direct 300 mAh Replacement Battery GDX-BAT-300

Care and limits

  • Two-point calibration with the High and Low Standards is recommended; a factory calibration is stored on the sensor
  • The PVC membrane module wears out and ages even on the shelf; replace it when response drops and do not stock spares far ahead
  • Do not soak for more than 24 hours; store long term in the storage bottle with a damp sponge
  • Never immerse above the BNC junction; the amplifier is not water resistant

Specifications are as published by Vernier, checked on 18 November 2026. Descriptions are written by Stemious. Vernier products are designed for education and are not for medical, industrial or research-grade commercial use. Vernier and Go Direct are trademarks of Vernier Science Education.

With Stemious in India

1 experiment in the Stemious appEach one runs step by step with this sensor: read it first, then do it with live data, photos and notes.
Mapped to your boardUsed in chapters of IB (1 chapter).
Supplied and supported hereStemious is Vernier's partner in India: quote, delivery, setup and teacher support from Pune.

School experiments that use it