Nitrate ion concentration in water and soil extracts

A nitrate ion-selective electrode supplied attached to a Go Direct ISE Amplifier, for measuring nitrate (NO3-) concentration in water samples in mg/L or mV. The gel-filled combination electrode has a replaceable PVC membrane module and a BNC connection, so worn parts can be changed without replacing the whole sensor. It connects by Bluetooth or USB.

Type: wireless ISE (Go Direct ISE Amplifier with Nitrate ISE BNC electrode)

Price on requestWe quote for the full set your lab needs, with training and support.

What students do with it

  • Measure nitrate in stream, lake, well or tap water
  • Compare nitrate levels between water quality sampling sites
  • Practise two-point calibration and use of an ionic strength adjuster

What it records

  • Nitrate (mg/L)
  • Potential (mV)

What is in the box

  • Go Direct ISE Amplifier connected to a Go Direct Nitrate ISE BNC electrode
  • Micro USB Cable
  • 30 mL High Standard solution with SDS (100 mg/L NO3-)
  • 30 mL Low Standard solution with SDS (1 mg/L NO3-)
  • Short-Term ISE Soaking Bottle

What else you need

  • A computer, Chromebook, or iOS/Android device connected by Bluetooth or USB (no interface required), or a LabQuest 2 or LabQuest 3 (original LabQuest is not compatible)
  • Vernier Graphical Analysis app (or LabQuest App)
  • Also supported: Python, JavaScript, LabVIEW
  • Fresh standard solutions once the supplied 30 mL bottles run out
  • Ionic strength adjuster (2.0 M ammonium sulfate) for best accuracy

Accessories and replacement parts

  • Go Direct Nitrate ISE BNC (replacement electrode) GDX-NO3-BNC
  • Nitrate Replacement Module NO3-MOD
  • Standard NO3 ISE Solution, Low Concentration (1 mg/L) NO3-LST
  • Standard NO3 ISE Solution, High Concentration (100 mg/L) NO3-HST
  • Go Direct Charge Station GDX-CRG
  • Go Direct Sensor Clamp GDX-CLAMP
  • Go Direct Ammonium ISE BNC GDX-NH4-BNC
  • Go Direct Chloride ISE BNC GDX-CL-BNC
  • Go Direct Calcium ISE BNC GDX-CA-BNC
  • Go Direct Potassium ISE BNC GDX-K-BNC
  • Go Direct 300 mAh Replacement Battery GDX-BAT-300

Care and limits

  • Soak the tip in High Standard for 30 minutes, then do a two-point calibration before measuring.
  • Do not soak for more than 24 hours; for long-term storage keep it in the bottle over a damp sponge without the tip touching the sponge.
  • The membrane module has a limited life and degrades on the shelf, so order replacements only when needed.
  • Do not fully submerge; the BNC joint is not waterproof. Not recommended by Vernier for elementary or middle school. For educational use only; not intended for industrial, medical or commercial applications.

Specifications are as published by Vernier, checked on 18 November 2026. Descriptions are written by Stemious. Vernier products are designed for education and are not for medical, industrial or research-grade commercial use. Vernier and Go Direct are trademarks of Vernier Science Education.

With Stemious in India

1 experiment in the Stemious appEach one runs step by step with this sensor: read it first, then do it with live data, photos and notes.
Mapped to your boardUsed in chapters of IB (1 chapter).
Supplied and supported hereStemious is Vernier's partner in India: quote, delivery, setup and teacher support from Pune.

School experiments that use it