Sensors › Human physiology
Go Direct Spirometer
Lung volumes, flow rates, and respiratory parameters
A handheld spirometer for human physiology classes that derives air flow rate and lung volume from the differential pressure across its flow head, and also reports respiration rate. Extra channels correct the volume trace for baseline drift automatically. It connects over Bluetooth or USB, has a rechargeable battery, and is used with a disposable bacterial filter and mouthpiece for each student.
Type: wireless sensor (Bluetooth + USB, rechargeable)
What students do with it
- Measure tidal volume, vital capacity and other lung volumes
- Record forced expiratory volume and flow
- Compare breathing at rest, after exercise and in different body positions
- Model restricted airways such as asthma
- Measure respiration rate over time
What it records
- Flow Rate (L/s)
- Volume (L)
- Adjusted Volume (L)
- Cycle Volume (L)
- Respiration Rate (breaths/min)
- Differential Pressure (Pa)
What is in the box
- Go Direct Spirometer
- Disposable mouthpieces (3)
- Disposable bacterial filters (3)
- Nose clips (3)
- Micro USB cable
What else you need
- Computer, Chromebook, iOS or Android device with the Graphical Analysis app, or LabQuest 2 or LabQuest 3
- Not compatible with the original LabQuest or, without an interface, with Graphical Analysis GW
- A fresh bacterial filter and mouthpiece for every student (consumables)
- Optional: 2 L calibration syringe for volume adjustment; Python, JavaScript or LabVIEW for programming
Accessories and replacement parts
- Disposable Bacterial Filters, 10 Pack SPR-FIL10
- Disposable Bacterial Filters, 30 Pack SPR-FIL30
- Disposable Bacterial Filters, 50 Pack SPR-FIL50
- Disposable Mouthpieces, 30 Pack SPR-MP30
- Disposable Mouthpieces, 100 Pack SPR-MP100
- Noseclips, 10 Pack SPR-NOSE10
- Noseclips, 30 Pack SPR-NOSE30
- O2 Gas Sensor to Spirometer Adapter O2-SPR
- Go Direct Charge Station GDX-CRG
- Micro USB Cable CB-USB-MICRO
- USB-C to Micro USB Cable CB-USB-C-MICRO
- Go Direct 650 mAh Replacement Battery GDX-BAT-650
Care and limits
- Factory calibrated; the volume channel can be fine-tuned with a 2 L syringe (not included)
- Each person uses their own bacterial filter and mouthpiece; these are never shared. Wipe nose clips between users and wash them after the session
- The flow head is not to be removed or sterilized by the user; the unit is not water resistant and must never be immersed
- For educational use only: not for medical use, patient diagnosis or life support
Specifications are as published by Vernier, checked on 18 November 2026. Descriptions are written by Stemious. Vernier products are designed for education and are not for medical, industrial or research-grade commercial use. Vernier and Go Direct are trademarks of Vernier Science Education.